Residual Gas Analysis

Residual Gas Analysis - Pfeiffer Vacuum

Quadrupole mass spectrometers are the classic measuring instrument for evaluating residual gas composition in a vacuum system.

The ion currents supplied by the mass spectrometer for the mass-to-charge ratio of the gas components provide meaningful information about a vacuum system in the multiple phases of operation, whether for determining the tightness and the absence of contamination after setup or for its characterization when operating a vacuum process.

The pressure range which can be achieved in the vacuum system based on the design of the vacuum chamber and pumping system determines the selection of the mass spectrometer with respect to the detector. A Faraday detector is frequently sufficient in high vacuum, while a secondary electron multiplier is necessary in ultra-high vacuum to detect the very low gas densities.

Another key criterion is the mass range to be detected. In the traditional vacuum system, atmospheric gases such as nitrogen, oxygen, argon, water vapor, and, generally, contamination with light hydrocarbons are the main focus. In order to detect these gases, a quadrupole mass spectrometer for the range between 1 and 100 atomic mass units (amu) is ideal, as this demonstrates excellent mass separation in this range. If heavier gases and their components must also be detected, such as long-chain hydrocarbons, Pfeiffer Vacuum also offers mass filters for this purpose for 1 to 200 amu or 1 to 300 amu.

An open ion source is the best choice for most tasks in residual gas analysis, as they combine a robust design with high detection sensitivity. Tasks for which gas jets or gas streams must be analyzed can be advantageously mastered with a closed or a cross-beam ion source. For the ultra-high vacuum range, a grid ion source with an extremely low outgassing rate is also available.
Thanks to the precise configurability of Pfeiffer Vacuum quadrupole mass spectrometers due to the large number of components to choose from, the spectrometers can be optimally selected for all measurement tasks. Our product and application specialists with many years of experience are happy to advise you on the configuration of the appropriate residual gas analyser.

Applications










Page functions
  • How would you rate this page?

    Cancel

  • Recommend this page!

    Cancel

  • Social Networks:

Contact

Contact options

Our points of contact are available to you at any time:

Display contact options

E-mail

You can use our contact form to send your request or concern directly to us.

Contact Form

Address
Headquarters postal address

Pfeiffer Vacuum GmbH
Berliner Strasse 43
35614 Asslar
Germany

P.O. Box

Pfeiffer Vacuum GmbH
Postfach 1280
35608 Asslar
Germany

T +49 6441 802-0
F +49 6441 802-1202
info@pfeiffer-vacuum.de

Download Brochure

Copyright © 2014 Pfeiffer Vacuum GmbH