HiPace® 300 with TC 400, DN 100 ISO-F

Overview

PM P03 902
Order number: PM P03 902
Similar Image
  • Rugged, powerful turbopump with a pumping speed of up to 260 l/s for N2
  • Integrated TC 400 drive electronics
  • Ideal for analytical and industrial applications
  • For installation in any orientation
  • With integrated water cooling for maximum gas throughput
  • Flexible through the ability to employ up to 4 accessories
  • Ideal for fast cycles
  • Extensive accessories expand the range of applications

Technical data

Bearing Hybrid
Compression ratio for Ar > 1 · 1011
Compression ratio for H2 9 · 105
Compression ratio for He > 1 · 108
Compression ratio for N2 > 1 · 1011
Cooling method, optional Air
Cooling method, standard Water
Cooling water flow 50 l/h
Cooling water flow, max 50 l/h
Cooling water flow, min 50 l/h
Cooling water temperature 15-35 °C | 59-95 °F | 288-308 K
Current max. 12,5 A
Electronic drive unit with TC 400
Flange (in) DN 100 ISO-F
Flange (out) DN 16 ISO-KF/G ¼"
Fore-vacuum max. for N2 20 hPa | 15 Torr | 20 mbar
Gas throughput at full rotational speed for Ar 7 hPa·l/s
Gas throughput at full rotational speed for H2 > 14 hPa·l/s
Gas throughput at full rotational speed for He 20 hPa·l/s
Gas throughput at full rotational speed for N2 14 hPa·l/s
I/O interfaces RS-485, Remote
Interface, extended Profibus, DeviceNet, E74
Mounting orientation Any
Permissible magnetic field max. 5.5 mT
Power consumption max. 300 W
Protection category IP54
Pumping speed for Ar 255 l/s
Pumping speed for H2 220 l/s
Pumping speed for He 255 l/s
Pumping speed for N2 260 l/s
Rotation speed ± 2 % 60,000 rpm | 60,000 min-1
Rotation speed variable 35 – 100 %
Run-up time 1.8 min
Sound pressure level ≤50 dB(A)
Ultimate pressure without gas ballast < 1 · 10-7 hPa | < 7.5 · 10-8 Torr | < 1 · 10-7 mbar
Venting connection G 1/8"
Weight 7 kg | 15.43 lb

Accessories

Adapters (electrical)|Profibus

Remote adapter for RS-485(PM 061 649 -X)

Adapters (electrical)|Remote

Y-Connector, shielded, M12 for accessories(P 4723 013)
Supply socket TC 400/TM 700, straight(P 4723 100)
Supply bushing, angled, for TC 400/TM 700(P 4723 101)

Adapters (electrical)|RS-232/485

Y-Connector M12 to RS-485(P 4723 010)
USB converter to RS-485 interface(PM 061 207 -T)
Coupling M12 for RS-485(PM 061 270 -X)
Termination resistor for RS-485(PT 348 105 -T)
Power separator for RS-485(PT 348 132 -T)

Cables|Backing pump control cables

Control cable for pumping stations 0.7 m(PM 061 675 AT)
HiPace – ACP connection cable(PM 071 142 -X)

Cables|Connection cables

Connection cable for HiPace with TC 400/TM 700 to power supply pack TPS/DCU 310/311/400/401(PM 061 352 -T)

Cables|Extension cables

Extension cable M12 on M12(PM 061 747 -T)

Cables|Mains cables / Power cords

Mains cable 230 V AC, CEE 7/7 to C13, 3 m(P 4564 309 ZA)
Mains cable 115 V AC, NEMA 5-15 to C13, 3 m(P 4564 309 ZE)
Mains cable 208 V AC, NEMA 6-15 to C13, 3 m(P 4564 309 ZF)

Cables|RS-485 Interface cables

Interface cable, M12 m straight/M12 m straight, 3 m(PM 061 283 -T)
Interface cable, M12 m straight/ M12 m angled, 0.7 m(PM 061 791 -T)

Control Devices|Backing pump

Relay box for backing pumps, single phase 20 A for TC 400 and TCP 350, M12 plug(PM 061 375 -T)
Relay box, shielded, for backing pumps, 1-phase 7 A for TC 400/1200, TM 700 and TCP 350, M12(PM 071 284 -X)

Control Devices|Power supplies and control displays

HPU 001, Handheld programming unit(PM 051 510 -T)
Accessories package for HPU 001/PC(PM 061 005 -T)
TPS 310, power supply pack for wall/standard rail fitting(PM 061 342 -T)
TPS 311, power supply pack 3HU 19" rack module(PM 061 346 -T)
DCU 002, Display Control Unit(PM 061 348 AT)
Front panel kit for TPS 311(PM 061 395 -T)
DCU 310, Display control unit with power supply pack(PM C01 822)

Cooling|Air cooling

Air cooling for HiPace 300 with TC 400(PM Z01 302)
Air cooling for HiPace 300/450, 115 V(PM Z01 308)
Air cooling for HiPace 300/450, 230 V(PM Z01 309)

Cooling|Water cooling

Water cooling for HiPace 300 with tube fitting 1/4"(PM 016 637 -T)

Monitoring|Pressure Sensors

RPT 010, Digital Piezo/Pirani Sensor(PT R71 100)
IKT 010, Digital cold cathode sensor, low current(PT R72 100)
IKT 011, Digital cold cathode sensor, high current(PT R73 100)

Monitoring|Sealing gas monitoring units

Sealing gas monitoring unit G 1/8"(PM 016 911 -U)

Mounting|DN ISO-F, Mounting kits

Mounting kit for DN 100 ISO-F, including coated centering ring, hexagon screws(PM 016 450 -T)
Mounting kit for DN 100 ISO-F, including coated centering ring, splinter shield, hexagon screws(PM 016 451 -T)
Mounting kit for DN 100 ISO-F, including coated centering ring, protective screen, hexagon screws(PM 016 452 -T)
Mounting kit for DN 100 ISO-F, including coated centering ring, stud screws(PM 016 455 -T)
Mounting kit for DN 100 ISO-F, including coated centering ring, splinter shield, stud screws(PM 016 456 -T)
Mounting kit for DN 100 ISO-F, including coated centering ring, protection screen, stud screws(PM 016 457 -T)

Mounting|DN ISO-K/-F, sealings

Centering ring with multifunction coating, DN 100 ISO-K/-F(PM 016 210 -U)

Mounting|Wall rail fittings

Wall rail fitting for TPS 110/180/310/400(PM 061 392 -T)

Other

TIC 010, Adapter for two sensors(PT R70 000)

Protection|DN ISO-K/-F, sealings, splinter shields, protection screens

Centering ring with multifunction coating and integrated splinter shield, DN 100 ISO-K/-F(PM 016 211 AU)
Centering ring with multifunction coating and integrated protection screen, DN 100 ISO-K/-F(PM 016 212 AU)
Centering ring with multifunction coating and integrated splinter shield, DN 100 ISO-K/-F(PM 016 807 -U)

Protection|Sealing gas throttles

Sealing gas throttle for HiPace 300(PM Z01 317)

Valves|Fore-vacuum safety valves

TVV 001, fore-vacuum safety valve, 230 V AC(PM Z01 205)
TVV 001, fore-vacuum safety valve, 115 V AC(PM Z01 206)

Valves|Sealing gas valves, shielded (normally closed)

Sealing gas valve, shielded for HiPace 300 with TC 400 and TM 700, TCP 350(PM Z01 312)

Venting|Power failure venting units (normally open)

Power failure venting valve, shielded, 24 V DC, G 1/8" for connection to TC 400, TM 700 and TC 1200(PM Z01 331)

Venting|Venting accessories

Screw-on flange, DN 16 ISO-KF, G 1/8"(PM 016 780 -T)
Push-in fitting for 6 mm tube, G 1/8"(PM 016 781 -T)
Push-in fitting for 8 mm tube, G 1/8"(PM 016 782 -T)
Hose nozzle for 9 mm hose, G 1/8"(PM 016 783 -T)
Banjo fitting(PM 016 787 -T)
Screw-in flange, DN 10 ISO-KF, G 1/8"(PM 033 737 -T)
Banjo fitting, small(PM 143 877 -T)
TTV 001, Drier for Venting Turbopumps(PM Z00 121)

Venting|Venting valves (normally closed)

Venting valve, shielded, 24 V DC, G 1/8", for connection to TC 400/1200 and TM 700(PM Z01 291)
Venting valve, shielded, 24 V DC, G1/8“ for connecting to TC 400, 1200 as well as TM 700 with an 270° angled plug(PM Z01 292)

Vibration Reduction|Vibration dampers

Vibration damper for HiPace 300/400, DN 100 ISO-K/F(PM 006 459 -X)

Dimensions

Dimension-TIM-RS

Characteristic

Characteristic-TIM-RS-1