ASI 35 with control panel (cable length 1.8 m), 3.5 m cable length to the Electronic module, sniffing option, fully configurable I/O interface
Overview
- Control panel with 1.8 m cable length
- 3.5 m cable length between the Vacuum module and the Electronic module
- Sniffing option allowing high admissible flow and multiprobes set-up
- Fully configurable I/O interface (37 pins D-Sub), with live status visible on the Control panel
- Ethernet, USB and RS-232 available as serial interfaces
- Restricted access to the settings menu to avoid any wrong manipulation while the system is in operation
- Universal voltage: no possible mistake whatever the country where the leak detection system is prepared and installed
- High helium pumping speed for optimized response time
Technical data
517-Pumping speed for He: High sensitivity leak test mode: | 6 l/s |
Dimensions Control panel (L x W x H) | 241 x 54 x 133 mm | 9.49 x 2.13 x 5.24 inch |
Dimensions Electronic module (L x W x H) | 216 x 317 x 111 mm | 8.5 x 12.48 x 4.37 inch |
Dimensions Vacuum module (L x W x H) | 279 x 264 x 197 mm | 10.98 x 10.39 x 7.76 inch |
Flange (in) | 1 flange: DN 25 ISO-KF; 2 flanges: DN 16 ISO-KF |
I/O interfaces | 6 Digital inputs (Allocated functions configurable); 3 Analog outputs (Configurable : Helium signal log, Mantissa, Exponent, Inlet pressure); 5 Relays outputs (Allocated functions configurable); 4 Transistor/open collector outputs (Allocated functions con |
Interfaces | RS-232, USB |
Max. inlet test pressure | Gross leak test mode: 18 hPa; Normal leak test mode: 1 hPa; High sensitivity test mode: 0.2 hPa |
Operating temperature | 10-45 |
Power consumption max. | 300 W |
Pumping speed for He: Normal leak test mode: | 1.8 l/s |
Start-up time (20°C) without calibration | ~ 3 min |
Supply | 90-240 V, 50/60 Hz |
Test method | Vacuum and sniffing leak detection |
Warranty: Year(s) | 3 |
Weight: Control panel | 1.3 kg | 2.87 lb |
Weight: Electronic module: | 5 kg | 11.02 lb |
Weight: Vacuum module | 15 kg | 33.07 lb |
Accessories
Remote control
Helium spray gun
Helium spray gun, standard (112535)
Specific communication interface
I/O module type ASI 20 MD (123352)
Sniffer probe
Dimensions
Downloads
File | Type | Language | Date | Filesize | Action |
---|---|---|---|---|---|
Data sheet | EN | 04-20-2018 | ~ 494.9 KB | Download |
File | Type | Language | Date | Filesize | Action |
---|---|---|---|---|---|
ASI 35 - Maintenance Instruction (123356MEN_02) | EN | 07-04-2017 | ~ 2.5 MB | Download | |
Operating instructions ASI 35 - Utilisation (123356OEN_02) | EN | 07-04-2017 | ~ 1.9 MB | Download | |
Operating instructions RS232 Communication Protocol - Detectors 3G - Operating (122215OEN_05) | EN | 11-30-2015 | ~ 1.1 MB | Download | |
Operating instructions RS232 Communication Protocol - Detectors 3G - Memo (122215CEN_03) | EN | 11-30-2015 | ~ 102.3 KB | Download | |
Operating instructions Sniffing Kit (ASI 35) - Installation (123589IEN_02) | EN | 07-05-2017 | ~ 608.8 KB | Download | |
Operating instructions Calibration kit (ASI 35) - Installation (123588IEN_02) | EN | 07-05-2017 | ~ 495.5 KB | Download | |
Operating instructions 37 pin I/O Interface - Operating (123894OEN_03) | EN | 03-22-2018 | ~ 2.1 MB | Download | |
Operating instructions 37 pin I/O Interface - Installation (123895IEN_03) | EN | 03-22-2018 | ~ 1.1 MB | Download |