Product Selector
Residual gas analysis in ultra high vacuum - Pfeiffer Vacuum

PrismaPlus® QMG 220 M3, 1-300 amu

This modularly designed compact mass spectrometer can be optimally adapted to your application

Product description

  • Mass range 1-300 amu for residual gas analysis and analytical measurement tasks, even in the higher measurement range
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
  • High measuring speed, stability and resolution
  • Interchangeability of analyzers and electronics
  • Optimum availability thanks to two filaments

PrismaPlus® QMG 220 M3 with open ion source

  • Ion source with very high sensitivity and linearity; for residual gas analysis and analytical tasks in the high and ultra high vacuum ranges
  • Optimum availability thanks to two filaments
  • Mass range 1-300 amu for residual gas analysis and analytical measurement tasks, even in the higher measurement range
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
  • Interchangeability of analyzers and electronics
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 311 111
Tungsten 200 90° PT M06 311 120
Yttriated iridium 200 I/O 220 PT M06 312 111

PrismaPlus® QMG 220 M3 with gas-tight ion source

  • For use in combination with gas inlet systems; low gas consumption, high signal-to-noise ratio
  • Optimum availability thanks to two filaments
  • Mass range 1-300 amu for analytical measurement tasks, even in the higher measurement range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 321 111
Yttriated iridium 200 I/O 220 PT M06 322 111

PrismaPlus® QMG 220 M3 with crossbeam ion source

  • For direct gas inlet, without interaction with the walls of the ion source
  • For use in combination with gas inlet systems
  • Optimum availability thanks to two filaments
  • Mass range 1-300 amu for optimum resolution and maximum sensitivity
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 331 111

PrismaPlus® QMG 220 M3 with grid ion source

  • Specially designed for residual gas analysis under UHV; minimum outgassing and desorption rates
  • Optimum availability thanks to two filaments
  • Mass range 1-300 amu for residual gas analysis, even in the higher mass range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 341 111
Your local contact
Pfeiffer Vacuum Inc.
24 Trafalgar Square
NH 03063-1988 Nashua
USA

+1 (800) 248-8254
+1 (888) 658-7983
write message