Product Selector
超高真空中的残余气体分析 - 普发真空

QR-Code

PT M16 112 211
Similar Image

PrismaPro® QMG 250 M1, 1–100 u, open ion source, Yttriated iridium, I/O-option: Extended
Order number: PT M16 112 211

  • PV MassSpec software for Windows 10, 8.1 & 7 for recording, saving and displaying measured data
  • Leak detection and vacuum diagnosis with a click
  • Easy definition of measurement recipes
  • Low detection limit
Bakeout temperature: analyzer 300 °C | 572 °F | 573 K
Connection
Connection for gauge Connection for an ActiveLine or DigiLine transmitter with analog relay option
Contribution to neighboring mass: 40 to 41 10 ppm
Detection limit min.: C-SEM (hPa) 3 · 10-15 hPa | 2.25 · 10-15 Torr | 3 · 10-15 mbar
Filament Yttriated iridium
Flange (in) DN 40 CF-F
I/O interfaces I/O-250
Input: Analog 1x ± 10 V / 12 Bit; 8x ± 10 V / 16 Bit
Input: Digital 7x, 24 V
Interfaces Ethernet
Ion source Open, 2 filaments
Mass range 1 – 100 u
Mounting orientation Any
Operating pressure max.: C-SEM 5 · 10-5 hPa | 3.75 · 10-5 Torr | 5 · 10-5 mbar
Operating pressure max.: Faraday 5 · 10-4 hPa | 3.75 · 10-4 Torr | 5 · 10-4 mbar
Operating temperature: analyzer 150 °C | 302 °F | 423 K
Operating temperature: electronics 5-50 °C | 41-122 °F | 278-323 K
Output: Analog 8x 0 – 10 V / 16 Bit
Output: Digital 10x, 24 V
Peak ratio reproducibility 0.5 %
Relay: Number 1 Pcs.
Resolution, adjustable at 10 % peak height 0.5 – 2.5 u
Rod system: Diameter 6 mm | 0.24 inch
Rod system: Length 125 mm | 4.92 inch
Scan speed 1 ms/amu - 16 s/amu
Sensitivity for Ar: Faraday 5 · 10-4 A/hPa
Supply: Voltage V AC 100 – 240 V AC
Temperature: Storage -25-70 °C | -13-158 °F | 248-343 K
Weight 3.2 kg | 7.05 lb

Massbild-TIM-RS

Accessories analog/relay

Gauge cable DigiLine xPT 200 AR to TPG 2xx, 3 m PT 348 250 -T

PKR 360, low current

PKR 360, low current, DN 40 CF-F PT T02 350 010

PKR 361, high current

PKR 361, high current, DN 40 CF-F PT T03 350 010

PBR 260 Pirani/Bayard-Alpert Hot Cathode gauge

PBR 260, Pirani/Bayard-Alpert, DN 25 ISO-KF PT R27 000

TPR 280 Pirani

TPR 280, 80 °C, DN 16 ISO-KF PT R26 950

Accessory for PrismaPlus QMG 220

Sensor cable PKR-QME, 0.6 m PT 448 249 -T

PPT 200 Pirani

PPT 200 AR, DN 16 ISO-KF, RS-485, analog PT R38 131

HPT 200 Pirani/Bayard-Alpert

HPT 200 AR, DN 40 CF-F, RS-485, analog PT R39 351

MPT 200 Pirani/Cold cathode

MPT 200, DN 40 CF-F, RS-485, analog PT R40 351
File Type Language Date Filesize
Data sheet PDF EN 08-18-2018 ~ 383.2 KB
Stepfile STP EN 03-14-2018 ~ 9.6 MB
File Type Language Date Filesize
Operating instructions QMG 250 PrismaPro® - Compact Mass Spectrometer (BG6001BEN_B) PDF EN 07-26-2018 ~ 6.5 MB
Operating instructions QMG 250 PrismaPro® - Web UI (BG6002BEN_B) PDF EN 07-30-2018 ~ 3.1 MB
Operating instructions QMG 250 PrismaPro® - Quick-Start Guide (BG6003BEN_B) PDF EN 07-31-2018 ~ 2.1 MB
Your local contact
Pfeiffer Vacuum Inc.
24 Trafalgar Square
NH 03063-1988 Nashua
USA

+1 (800) 248-8254
+1 (888) 658-7983
write message

This website uses cookies to ensure you get the best experience on our website. More info