ASI 35 with control panel (cable length 1.8 m), 3.5 m cable length to the electronic module, sniffing option, fully configurable I/O interface
Order number: S12S0102MM9A

  • Control panel with 1.8 m cable length
  • 3.5 m cable length between the Vacuum module and the Electronic module
  • Sniffing option allowing high admissible flow and multiprobes set-up
  • Fully configurable I/O interface (37 pins D-Sub), with live status visible on the Control panel
  • Ethernet, USB and RS-232 available as serial interfaces
  • Restricted access to the settings menu to avoid any wrong manipulation while the system is in operation
  • Universal voltage: no possible mistake whatever the country where the leak detection system is prepared and installed
  • High helium pumping speed for optimized response time
517-Pumping speed for He: High sensitivity leak test mode: 6 l/s
Cable length to electronics module 3.5 m
Cable length to operator panel 1.8 m
Connection flange (in) 1x DN 25 ISO-KF; 2x DN 16 ISO-KF
Detectable gases 4He
3He
H2
Dimensions Control panel (L x W x H) 241 x 54 x 133 mm | 9.49 x 2.13 x 5.24 inch
Dimensions Electronic module (L x W x H) 216 x 317 x 111 mm | 8.5 x 12.48 x 4.37 inch
Dimensions Vacuum module (L x W x H) 279 x 264 x 197 mm | 10.98 x 10.39 x 7.76 inch
I/O interfaces RS-232, USB
Inlet test pressure max. Gross leak test mode: 18 hPa | Normal leak test mode: 1 hPa | High sensitivity test mode: 0.2 hPa  
Input voltage(s) 90 – 240 V AC, 50/60 Hz  
Interface: Connection, device side 6 Digital inputs (Allocated functions configurable); 3 Analog outputs (Configurable : Helium signal log, Mantissa, Exponent, Inlet pressure); 5 Relays outputs (Allocated functions configurable); 4 Transistor/open collector outputs
Minimum detectable leakage rate for helium (sniffing leak detection) 1.5 · 10-9 Pa m3/s | 1.12 · 10-8 Torr l/s | 1.5 · 10-8 mbar l/s
Minimum detectable leakage rate for helium (vacuum leak detection) Gross leak test mode: 3.5 · 10-9 Pa m³/s | 1 · 10-11 Pa m³/s | High-sensitivity leak test mode: 5 · 10-13 Pa m³/s  
Operating temperature 10-45 °C | 50-113 °F | 283-318 K
Power consumption max. 300 W
Pumping speed for He: Normal leak test mode: 1.8 l/s
Start-up time (20°C) without calibration ~ 3 min
Test method Vacuum and sniffing leak detection
Warranty: Year(s) 3
Weight: Control panel 1.3 kg | 2.87 lb
Weight: Electronic module 5 kg | 11.02 lb
Weight: Vacuum module 15 kg | 33.07 lb