QR-Code

S22X0102MM9A
Similar Image

ASI 35 with control panel (cable length 5 m), 3.5 m cable length to the electronic module, fully configurable I/O interface
Order number: S22X0102MM9A

  • Control panel with 5 m cable length
  • 3.5 m cable length between the Vacuum module and the Electronic module
  • Fully configurable I/O interface (37 pins D-Sub), with live status visible on the Control panel
  • USB and RS-232 available as serial interfaces
  • Restricted access to the settings menu to avoid any wrong manipulation while the system is in operation
  • Universal voltage: no possible mistake whatever the country where the leak detection system is prepared and installed
  • High helium pumping speed for optimized response time
517-Pumping speed for He: High sensitivity leak test mode: 6 l/s
Connection flange (in) 1 flange: DN 25 ISO-KF; 4 flanges: DN 16 ISO-KF
Detectable gases 4He, 3He, H2
Dimensions Control panel (L x W x H) 241 x 54 x 133 mm | 9.49 x 2.13 x 5.24 inch
Dimensions Electronic module (L x W x H) 216 x 317 x 111 mm | 8.5 x 12.48 x 4.37 inch
Dimensions Vacuum module (L x W x H) 279 x 264 x 197 mm | 10.98 x 10.39 x 7.76 inch
I/O interfaces 6 Digital inputs (Allocated functions configurable); 3 Analog outputs (Configurable : Helium signal log, Mantissa, Exponent, Inlet pressure); 5 Relays outputs (Allocated functions configurable); 4 Transistor/open collector outputs
Inlet test pressure max. Gross leak test mode: 18 hPa | Normal leak test mode: 1 hPa | High sensitivity test mode: 0.2 hPa  
Minimum detectable leakage rate for helium (vacuum leak detection) Gross leak test mode: 3.5 · 10-9 Pa m³/s | 1 · 10-11 Pa m³/s | High-sensitivity leak test mode: 5 · 10-13 Pa m³/s  
Power consumption max. 300 W
Pumping speed for He: Normal leak test mode: 1.8 l/s
Start-up time (20°C) without calibration ~ 3 min
Supply 90 – 240 V, 50/60 Hz
Test method Vacuum leak detection
Warranty: Year(s) 3
Weight: Control panel 1.3 kg | 2.87 lb
Weight: Electronic module: 5 kg | 11.02 lb
Weight: Vacuum module 15 kg | 33.07 lb

Dimension-TIM-RS

File Type Language Date Filesize
Data sheet PDF EN 10-23-2020 ~ 495.7 KB
File Type Language Date Filesize
ASI 35 - Maintenance Instruction (127801MEN_01) PDF EN 06-02-2020 ~ 4.8 MB
Operating instructions ASI 35 - Operation (127801OEN_01) PDF EN 06-02-2020 ~ 5.8 MB
Operating instructions RS232 Communication Protocol - Detectors 3G - Operating (122215OEN_05) PDF EN 11-30-2015 ~ 1.1 MB
Operating instructions RS232 Communication Protocol - Detectors 3G - Memo (122215CEN_03) PDF EN 11-30-2015 ~ 102.3 KB
Operating instructions 37 pin I/O Interface - Operating (123894OEN_03) PDF EN 06-25-2018 ~ 2.1 MB
Your local contact
Pfeiffer Vacuum Inc.
24 Trafalgar Square
NH 03063-1988 Nashua
USA

+1 (800) 248-8254
+1 (888) 658-7983
write message