QR-Code

SplitFlow™ 50 with TC 110, DN 63 CF-F
Order number: PM P04 342

  • Small yet powerful turbopump based on HiPace technology
  • With a pumping speed up to 53 l/s for N2 at the high vacuum flange and 0,15 l/s at interstage pumping
  • Integrated TC 110 drive electronics
  • For installation in any orientation
  • Ideal for analytical applications such as leak detection and mass spectrometry
  • Extensive accessories expand the range of applications
Bearing Hybrid
Compression ratio (interstage pumping/fore-vacuum) for Ar 1.5 · 103
Compression ratio (interstage pumping/fore-vacuum) for H2 2 · 101
Compression ratio (interstage pumping/fore-vacuum) for He 5 · 101
Compression ratio (interstage pumping/fore-vacuum) for N2 9 · 102
Compression ratio for Ar 2.1 · 1010
Compression ratio for H2 1.3 · 106
Compression ratio for He 1.8 · 106
Compression ratio for N2 1 · 108
Connection flange (in) DN 63 CF-F
Connection flange (out) G ¼"
Cooling method, optional Air/Water
Cooling method, standard Convection
Cooling water flow 75 l/h
Cooling water flow, max. 75 l/h
Cooling water flow, min. 75 l/h
Cooling water temperature 5-25 °C | 41-77 °F | 278-298 K
Current max. 4,6 A
Electronic drive unit TM 700
Final pressure without gas ballast 4 · 10-7 hPa | 3 · 10-7 Torr | 4 · 10-7 mbar
Flange (interstage pumping) M5
Fore-vacuum max. for N2 20 hPa | 15 Torr | 20 mbar
Gas throughput at full rotational speed for Ar 0.46 hPa·l/s
Gas throughput at full rotational speed for H2 110 hPa·l/s
Gas throughput at full rotational speed for He 7.3 hPa·l/s
Gas throughput at full rotational speed for N2 1.8 hPa·l/s
I/O interfaces RS-485, Remote
Mounting orientation Any
Operating voltage: V DC 24 (± 5 %) V DC
Permissible radial magnetic field max. 5 mT
Power consumption max. 110 W
Protection category IP54
Pumping speed (interstage pumping) for Ar 0.13 l/s
Pumping speed (interstage pumping) for H2 0.3 l/s
Pumping speed (interstage pumping) for He 0.16 l/s
Pumping speed (interstage pumping) for N2 0.15 l/s
Pumping speed for Ar 53 l/s
Pumping speed for H2 21 l/s
Pumping speed for He 27 l/s
Pumping speed for N2 53 l/s
Rotation speed ± 2 % 49,000 rpm | 49,000 min-1
Run-up time 1.3 min
Sound pressure level ≤48 dB(A)
Ultimate pressure according to PNEUROP < 4 · 10-7 hPa | < 3 · 10-7 Torr | < 4 · 10-7 mbar
Venting connection G 1/8"
Weight 3.7 kg | 8.16 lb

Dimension-TIM-RS

Characteristic-TIM-RS-1

File Type Language Date Filesize
Data sheet PDF EN 05-29-2020 ~ 146.6 KB
Stepfile STP EN 12-16-2010 ~ 1.5 MB
File Type Language Date Filesize
Operating instructions SplitFlow 50 with TC 110 (PT0322BEN_H) PDF EN 05-03-2016 ~ 3.9 MB
Operating instructions TC 110, Electronic drive unit for HiPace (PT0204BEN_V) PDF EN 12-12-2019 ~ 1.7 MB
Your local contact
Pfeiffer Vacuum Inc.
24 Trafalgar Square
NH 03063-1988 Nashua
USA

+1 (800) 248-8254
+1 (888) 658-7983
write message