Pfeiffer Vacuum

PrismaPlus® QMG 220 M2, 1-200 amu

This modularly designed compact mass spectrometer can be optimally adapted to your application

Product description

  • Mass range 1-200 amu for residual gas analysis and analytical measurement tasks, even in the higher measurement range
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
  • High measuring speed, stability and resolution
  • Interchangeability of analyzers and electronics
  • Optimum availability thanks to two filaments

PrismaPlus® QMG 220 M2 with open ion source

  • Ion source with very high sensitivity and linearity; for residual gas analysis and analytical tasks in the high and ultra high vacuum ranges
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for residual gas analysis and analytical measurement tasks, even in the higher measurement range
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 211 111
Yttriated iridium 200 I/O 220 PT M06 212 111
Yttriated iridium 200 90° I/O 220 PT M06 212 221

PrismaPlus® QMG 220 M2 with gas-tight ion source

  • For use in combination with gas inlet systems; low gas consumption, high signal-to-noise ratio
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for analytical measurement tasks, even in the higher measurement range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 221 111
Tungsten 200 90° I/O 220 PT M06 221 121
Yttriated iridium 200 I/O 220 PT M06 222 111

PrismaPlus® QMG 220 M2 with crossbeam ion source

  • For direct gas inlet, without interaction with the walls of the ion source
  • For use in combination with gas inlet systems
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for analytical tasks, even in the higher measurement range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 PT M06 231 110
Tungsten 200 I/O 220 PT M06 231 111

PrismaPlus® QMG 220 M2 with grid ion source

  • Specially designed for residual gas analysis under UHV; minimum outgassing and desorption rates
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for residual gas analysis, even in the higher mass range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 241 111

Product Overview

No items selected

Favorites

You have not selected any article to add to your favorites

Compare Products

There are no products selected for comparison.

Your local contact

Pfeiffer Vacuum Inc.
24 Trafalgar Square
NH 03063-1988 Nashua
USA

T: +1 (800) 248-8254
F: +1 (888) 658-7983

This website uses cookies to ensure you get the best experience on our website. More info