OmniStar® GSD 350 O

Select the smallest mass range with which the set measuring tasks can be performed. This ensures maximum sensitivity.

Product description

  • Gas inlet with stainless steel capillary and inlet valve

OmniStar® GSD 350 O1, 1–100 u

  • Mass range 1–100 u
  • Standard devices with heatable capillary hose up to 200 °C
  • Variants with heatable capillary hose up to 350 °C
  • Filament material: choose between tungsten or Y2O3-coated iridium
  • Variants for corrosive gases
Filament Gas connection: Length [m] Operating temperature: capillary, up to [°C] Calibration unit Corrosive gas version Part number
Iridium coated with Y2O3 1 200 No No PT Q80 217 110
Tungsten 1 200 No No PT Q80 617 110
Iridium coated with Y2O3 2 200 No No PT Q80 217 210
Tungsten 2 200 No No PT Q80 617 210
Tungsten 1 350 No No PT Q80 617 310
Iridium coated with Y2O3 1 350 No No PT Q80 217 310

OmniStar® GSD 350 O2, 1-200 u

  • Mass range 1–200 u
  • Standard devices with heatable capillary hose up to 200 °C
  • Variants with heatable capillary hose up to 350 °C
  • Filament material: choose between tungsten or Y2O3-coated iridium
  • Variants for corrosive gases
Filament Gas connection: Length [m] Operating temperature: capillary, up to [°C] Calibration unit Corrosive gas version Part number
Iridium coated with Y2O3 1 200 No No PT Q80 217 120
Tungsten 1 200 No No PT Q80 617 120
Iridium coated with Y2O3 2 200 No No PT Q80 217 220
Tungsten 2 200 No No PT Q80 617 220
Iridium coated with Y2O3 1 350 No No PT Q80 217 320
Tungsten 1 350 No No PT Q80 617 320

OmniStar® GSD 350 O3, 1-300 u

  • Mass range 1–300 u
  • Standard devices with heatable capillary hose up to 200 °C
  • Variants with heatable capillary hose up to 350 °C
  • Filament material: choose between tungsten or Y2O3-coated iridium
  • Variants with calibration device for calibrating the mass scale
  • Variants for corrosive gases
Filament Gas connection: Length [m] Operating temperature: capillary, up to [°C] Calibration unit Corrosive gas version Part number
Iridium coated with Y2O3 1 200 No No PT Q80 217 130
Tungsten 1 200 No No PT Q80 617 130
Iridium coated with Y2O3 2 200 No No PT Q80 217 230
Tungsten 2 200 No No PT Q80 617 230
Iridium coated with Y2O3 1 350 No No PT Q80 217 330
Tungsten 1 350 No No PT Q80 617 330
Iridium coated with Y2O3 1 200 Yes No PT Q80 117 130
Tungsten 1 200 Yes No PT Q80 517 130
Iridium coated with Y2O3 2 200 Yes No PT Q80 117 230
Tungsten 2 200 Yes No PT Q80 517 230
Iridium coated with Y2O3 1 350 Yes No PT Q80 117 330
Tungsten 1 350 Yes No PT Q80 517 330

OmniStar® GSD 350 O1C, 1–100 u

  • Mass range 1–100 u
  • Standard devices with heatable capillary hose up to 200 °C
  • Variants with heatable capillary hose up to 350 °C
  • Filament material: choose between tungsten or Y2O3-coated iridium
  • Variants for corrosive gases
Filament Gas connection: Length [m] Operating temperature: capillary, up to [°C] Calibration unit Corrosive gas version Part number
Iridium coated with Y2O3 1 200 No Yes PT Q81 217 110
Tungsten 1 200 No Yes PT Q81 617 110
Iridium coated with Y2O3 2 200 No Yes PT Q81 217 210
Tungsten 2 200 No Yes PT Q81 617 210
Iridium coated with Y2O3 1 350 No Yes PT Q81 217 310
Tungsten 1 350 No Yes PT Q81 617 310

OmniStar® GSD 350 O2C, 1-200 u

  • Mass range 1–200 u
  • Standard devices with heatable capillary hose up to 200 °C
  • Variants with heatable capillary hose up to 350 °C
  • Filament material: choose between tungsten or Y2O3-coated iridium
  • Variants for corrosive gases
Filament Gas connection: Length [m] Operating temperature: capillary, up to [°C] Calibration unit Corrosive gas version Part number
Iridium coated with Y2O3 1 200 No Yes PT Q81 217 120
Tungsten 1 200 No Yes PT Q81 617 120
Iridium coated with Y2O3 2 200 No Yes PT Q81 217 220
Tungsten 2 200 No Yes PT Q81 617 220
Iridium coated with Y2O3 1 350 No Yes PT Q81 217 320
Tungsten 1 350 No Yes PT Q81 617 320

OmniStar® GSD 350 O3C, 1-300 u

  • Mass range 1–300 u
  • Standard devices with heatable capillary hose up to 200 °C
  • Variants with heatable capillary hose up to 350 °C
  • Filament material: choose between tungsten or Y2O3-coated iridium
  • Variants with calibration device for calibrating the mass scale
  • Variants for corrosive gases
Filament Gas connection: Length [m] Operating temperature: capillary, up to [°C] Calibration unit Corrosive gas version Part number
Iridium coated with Y2O3 1 200 No Yes PT Q81 217 130
Tungsten 1 200 No Yes PT Q81 617 130
Iridium coated with Y2O3 2 200 No Yes PT Q81 217 230
Tungsten 2 200 No Yes PT Q81 617 230
Tungsten 1 350 No Yes PT Q81 617 330
Iridium coated with Y2O3 1 350 No Yes PT Q81 217 330
Iridium coated with Y2O3 1 200 Yes Yes PT Q81 117 130
Tungsten 1 200 Yes Yes PT Q81 517 130
Iridium coated with Y2O3 2 200 Yes Yes PT Q81 117 230
Tungsten 2 200 Yes Yes PT Q81 517 230
Iridium coated with Y2O3 1 350 Yes Yes PT Q81 117 330
Tungsten 1 350 Yes Yes PT Q81 517 330
Your local contact
Pfeiffer Vacuum Inc.
24 Trafalgar Square
NH 03063-1988 Nashua
USA

+1 (800) 248-8254
+1 (888) 658-7983