ThermoStar® GSD 350 T
Select the smallest mass range with which the set measuring tasks can be performed. This ensures maximum sensitivity.
Product description
- Gas inlet with quartz capillary, continuously open
ThermoStar® GSD 350 T1, 1 – 100 u
- Mass range 1 – 100 u
- Standard devices with heatable capillary hose up to 200°C
- Variants with heatable capillary hose up to 350°C
- Filament material: choose between tungsten or iridium coated with Y2O3
- Variants for corrosive gases
Filament | Gas connection: Length [m] | Operating temperature: capillary, up to [°C] | Calibration device | Corrosive gas version | Part number | |
---|---|---|---|---|---|---|
Iridium coated with Y2O3 | 1 | 200 | No | No | PT Q90 211 110 | |
Tungsten | 1 | 200 | No | No | PT Q90 611 110 | |
Iridium coated with Y2O3 | 2 | 200 | No | No | PT Q90 211 210 | |
Tungsten | 2 | 200 | No | No | PT Q90 611 210 | |
Iridium coated with Y2O3 | 1 | 350 | No | No | PT Q90 211 310 | |
Tungsten | 1 | 350 | No | No | PT Q90 611 310 |
ThermoStar® GSD 350 T2, 1 – 200 u
- Mass range 1 – 200 u
- Standard devices with heatable capillary hose up to 200°C
- Variants with heatable capillary hose up to 350°C
- Filament material: choose between tungsten or iridium coated with Y2O3
- Variants for corrosive gases
Filament | Gas connection: Length [m] | Operating temperature: capillary, up to [°C] | Calibration device | Corrosive gas version | Part number | |
---|---|---|---|---|---|---|
Iridium coated with Y2O3 | 1 | 200 | No | No | PT Q90 211 120 | |
Tungsten | 1 | 200 | No | No | PT Q90 611 120 | |
Iridium coated with Y2O3 | 2 | 200 | No | No | PT Q90 211 220 | |
Tungsten | 2 | 200 | No | No | PT Q90 611 220 | |
Iridium coated with Y2O3 | 1 | 350 | No | No | PT Q90 211 320 | |
Tungsten | 1 | 350 | No | No | PT Q90 611 320 |
ThermoStar® GSD 350 T3, 1 – 300 u
- Mass range 1 – 300 u
- Standard devices with heatable capillary hose up to 200°C
- Variants with heatable capillary hose up to 350°C
- Filament material: choose between tungsten or iridium coated with Y2O3
- Variants with calibration device for calibrating the mass scale
- Variants for corrosive gases
Filament | Gas connection: Length [m] | Operating temperature: capillary, up to [°C] | Calibration device | Corrosive gas version | Part number | |
---|---|---|---|---|---|---|
Iridium coated with Y2O3 | 1 | 200 | No | No | PT Q90 211 130 | |
Tungsten | 1 | 200 | No | No | PT Q90 611 130 | |
Iridium coated with Y2O3 | 2 | 200 | No | No | PT Q90 211 230 | |
Tungsten | 2 | 200 | No | No | PT Q90 611 230 | |
Iridium coated with Y2O3 | 1 | 350 | No | No | PT Q90 211 330 | |
Tungsten | 1 | 350 | No | No | PT Q90 611 330 | |
Iridium coated with Y2O3 | 1 | 200 | Yes | No | PT Q90 111 130 | |
Tungsten | 1 | 200 | Yes | No | PT Q90 511 130 | |
Iridium coated with Y2O3 | 2 | 200 | Yes | No | PT Q90 111 230 | |
Tungsten | 2 | 200 | Yes | No | PT Q90 511 230 | |
Iridium coated with Y2O3 | 1 | 350 | Yes | No | PT Q90 111 330 | |
Tungsten | 1 | 350 | Yes | No | PT Q90 511 330 |
ThermoStar® GSD 350 T1C, 1 – 100 u
- Mass range 1 – 100 u
- Standard devices with heatable capillary hose up to 200°C
- Variants with heatable capillary hose up to 350°C
- Filament material: choose between tungsten or iridium coated with Y2O3
- Variants for corrosive gases
Filament | Gas connection: Length [m] | Operating temperature: capillary, up to [°C] | Calibration device | Corrosive gas version | Part number | |
---|---|---|---|---|---|---|
Iridium coated with Y2O3 | 1 | 200 | No | Yes | PT Q91 211 110 | |
Tungsten | 1 | 200 | No | Yes | PT Q91 611 110 | |
Iridium coated with Y2O3 | 2 | 200 | No | Yes | PT Q91 211 210 | |
Tungsten | 2 | 200 | No | Yes | PT Q91 611 210 | |
Iridium coated with Y2O3 | 1 | 350 | No | Yes | PT Q91 211 310 | |
Tungsten | 1 | 350 | No | Yes | PT Q91 611 310 |
ThermoStar® GSD 350 T2C, 1 – 200 u
- Mass range 1 – 200 u
- Standard devices with heatable capillary hose up to 200°C
- Variants with heatable capillary hose up to 350°C
- Filament material: choose between tungsten or iridium coated with Y2O3
- Variants for corrosive gases
Filament | Gas connection: Length [m] | Operating temperature: capillary, up to [°C] | Calibration device | Corrosive gas version | Part number | |
---|---|---|---|---|---|---|
Iridium coated with Y2O3 | 1 | 200 | No | Yes | PT Q91 211 120 | |
Tungsten | 1 | 200 | No | Yes | PT Q91 611 120 | |
Iridium coated with Y2O3 | 2 | 200 | No | Yes | PT Q91 211 220 | |
Tungsten | 2 | 200 | No | Yes | PT Q91 611 220 | |
Iridium coated with Y2O3 | 1 | 350 | No | Yes | PT Q91 211 320 | |
Tungsten | 1 | 350 | No | Yes | PT Q91 611 320 |
ThermoStar® GSD 350 T3C, 1 – 300 u
- Mass range 1 – 300 u
- Standard devices with heatable capillary hose up to 200°C
- Variants with heatable capillary hose up to 350°C
- Filament material: choose between tungsten or iridium coated with Y2O3
- Variants with calibration device for calibrating the mass scale
- Variants for corrosive gases
Filament | Gas connection: Length [m] | Operating temperature: capillary, up to [°C] | Calibration device | Corrosive gas version | Part number | |
---|---|---|---|---|---|---|
Iridium coated with Y2O3 | 1 | 200 | No | Yes | PT Q91 211 130 | |
Tungsten | 1 | 200 | No | Yes | PT Q91 611 130 | |
Iridium coated with Y2O3 | 2 | 200 | No | Yes | PT Q91 211 230 | |
Tungsten | 2 | 200 | No | Yes | PT Q91 611 230 | |
Iridium coated with Y2O3 | 1 | 350 | No | Yes | PT Q91 211 330 | |
Tungsten | 1 | 350 | No | Yes | PT Q91 611 330 | |
Iridium coated with Y2O3 | 1 | 200 | Yes | Yes | PT Q91 111 130 | |
Tungsten | 1 | 200 | Yes | Yes | PT Q91 511 130 | |
Iridium coated with Y2O3 | 2 | 200 | Yes | Yes | PT Q91 111 230 | |
Tungsten | 2 | 200 | Yes | Yes | PT Q91 511 230 | |
Iridium coated with Y2O3 | 1 | 350 | Yes | Yes | PT Q91 111 330 | |
Tungsten | 1 | 350 | Yes | Yes | PT Q91 511 330 |