PrismaPlus® QMG 220 M1, 1–100 amu
This modularly designed compact mass spectrometer can be optimally adapted to your application
Product description
- Mass range 1–100 amu for optimum resolution and maximum sensitivity
- Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
- High measuring speed, stability and resolution
- Interchangeability of analyzers and electronics
- Optimum availability thanks to two filaments
PrismaPlus® QMG 220 M1 with open ion source
- Ion source with very high sensitivity and linearity; for residual gas analysis and analytical tasks in the high and ultra high vacuum ranges
- Optimum availability thanks to two filaments
- Mass range 1–100 amu for optimum resolution and maximum sensitivity
- Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
Filament | Bakeout temperature: analyzer [°C] | Connection | I/O interfaces | Order number |
Tungsten | 200 | 0° | |
PT M06 111 110 |
|
Tungsten | 200 | 0° | I/O 220 |
PT M06 111 111 |
|
Tungsten | 200 | 90° | |
PT M06 111 120 |
|
Tungsten | 200 | 90° | I/O 220 |
PT M06 111 121 |
|
Tungsten | 200 | 0° | I/O 220 |
PT M06 111 211 |
|
Iridium coated with Y2O3 | 200 | 0° | I/O 220 |
PT M06 112 111 |
|
PrismaPlus® QMG 220 M1 with gas-tight ion source
- For use in combination with gas inlet systems; low gas consumption, high signal-to-noise ratio
- Optimum availability thanks to two filaments
- Mass range 1–100 amu for optimum resolution and maximum sensitivity
Filament | Bakeout temperature: analyzer [°C] | Connection | I/O interfaces | Order number |
Tungsten | 200 | 0° | |
PT M06 121 110 |
|
Tungsten | 200 | 0° | I/O 220 |
PT M06 121 111 |
|
Tungsten | 200 | 90° | |
PT M06 121 120 |
|
Tungsten | 200 | 90° | I/O 220 |
PT M06 121 121 |
|
Iridium coated with Y2O3 | 200 | 0° | I/O 220 |
PT M06 122 111 |
|
PrismaPlus® QMG 220 M1 with crossbeam ion source
- For direct gas inlet, without interaction with the walls of the ion source
- For use in combination with gas inlet systems
- Optimum availability thanks to two filaments
- Mass range 1–100 amu for optimum resolution and maximum sensitivity
Filament | Bakeout temperature: analyzer [°C] | Connection | I/O interfaces | Order number |
Tungsten | 200 | 0° | |
PT M06 131 110 |
|
Tungsten | 200 | 0° | I/O 220 |
PT M06 131 111 |
|
Tungsten | 200 | 90° | |
PT M06 131 120 |
|
Tungsten | 200 | 90° | I/O 220 |
PT M06 131 121 |
|
PrismaPlus® QMG 220 M1 with grid ion source
- Specially designed for residual gas analysis under UHV; minimum outgassing and desorption rates
- Optimum availability thanks to two filaments
- Mass range 1–100 amu for optimum resolution and maximum sensitivity
Filament | Bakeout temperature: analyzer [°C] | Connection | I/O interfaces | Order number |
Tungsten | 200 | 0° | |
PT M06 141 110 |
|
Tungsten | 200 | 0° | I/O 220 |
PT M06 141 111 |
|
Tungsten | 200 | 90° | |
PT M06 141 120 |
|
Tungsten | 200 | 90° | I/O 220 |
PT M06 141 121 |
|
Tungsten | 200 | 0° | |
PT M06 141 210 |
|