Product Selector
Residual gas analysis in ultra high vacuum - Pfeiffer Vacuum

PrismaPlus® QMG 220 M1, 1-100 amu

This modularly designed compact mass spectrometer can be optimally adapted to your application

Product description

  • Mass range 1-100 amu for optimum resolution and maximum sensitivity
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
  • High measuring speed, stability and resolution
  • Interchangeability of analyzers and electronics
  • Optimum availability thanks to two filaments

PrismaPlus® QMG 220 M1 with open ion source

  • Ion source with very high sensitivity and linearity; for residual gas analysis and analytical tasks in the high and ultra high vacuum ranges
  • Optimum availability thanks to two filaments
  • Mass range 1-100 amu for optimum resolution and maximum sensitivity
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 PT M06 111 110
Tungsten 200 I/O 220 PT M06 111 111
Tungsten 200 90° PT M06 111 120
Tungsten 200 90° I/O 220 PT M06 111 121
Tungsten 200 I/O 220 PT M06 111 211
Yttriated iridium 200 I/O 220 PT M06 112 111

PrismaPlus® QMG 220 M1 with gas-tight ion source

  • For use in combination with gas inlet systems; low gas consumption, high signal-to-noise ratio
  • Optimum availability thanks to two filaments
  • Mass range 1-100 amu for optimum resolution and maximum sensitivity
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 PT M06 121 110
Tungsten 200 I/O 220 PT M06 121 111
Tungsten 200 90° PT M06 121 120
Tungsten 200 90° I/O 220 PT M06 121 121
Yttriated iridium 200 I/O 220 PT M06 122 111

PrismaPlus® QMG 220 M1 with crossbeam ion source

  • For direct gas inlet, without interaction with the walls of the ion source
  • For use in combination with gas inlet systems
  • Optimum availability thanks to two filaments
  • Mass range 1-100 amu for optimum resolution and maximum sensitivity
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 PT M06 131 110
Tungsten 200 I/O 220 PT M06 131 111
Tungsten 200 90° PT M06 131 120
Tungsten 200 90° I/O 220 PT M06 131 121

PrismaPlus® QMG 220 M1 with grid ion source

  • Specially designed for residual gas analysis under UHV; minimum outgassing and desorption rates
  • Optimum availability thanks to two filaments
  • Mass range 1-100 amu for optimum resolution and maximum sensitivity
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 PT M06 141 110
Tungsten 200 I/O 220 PT M06 141 111
Tungsten 200 90° PT M06 141 120
Tungsten 200 90° I/O 220 PT M06 141 121
Tungsten 200 PT M06 141 210