PrismaPlus® QMG 220 M2, 1-200 amu

This modularly designed compact mass spectrometer can be optimally adapted to your application

Product description

  • Mass range 1-200 amu for residual gas analysis and analytical measurement tasks, even in the higher measurement range
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
  • High measuring speed, stability and resolution
  • Interchangeability of analyzers and electronics
  • Optimum availability thanks to two filaments

PrismaPlus® QMG 220 M2 with open ion source

  • Ion source with very high sensitivity and linearity; for residual gas analysis and analytical tasks in the high and ultra high vacuum ranges
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for residual gas analysis and analytical measurement tasks, even in the higher measurement range
  • Cost-effective residual gas analysis and vacuum process monitoring in the high and ultra high vacuum ranges
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 211 111
Yttriated iridium 200 I/O 220 PT M06 212 111
Yttriated iridium 200 90° I/O 220 PT M06 212 221

PrismaPlus® QMG 220 M2 with gas-tight ion source

  • For use in combination with gas inlet systems; low gas consumption, high signal-to-noise ratio
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for analytical measurement tasks, even in the higher measurement range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 221 111
Tungsten 200 90° I/O 220 PT M06 221 121
Yttriated iridium 200 I/O 220 PT M06 222 111

PrismaPlus® QMG 220 M2 with crossbeam ion source

  • For direct gas inlet, without interaction with the walls of the ion source
  • For use in combination with gas inlet systems
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for analytical tasks, even in the higher measurement range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 PT M06 231 110
Tungsten 200 I/O 220 PT M06 231 111

PrismaPlus® QMG 220 M2 with grid ion source

  • Specially designed for residual gas analysis under UHV; minimum outgassing and desorption rates
  • Optimum availability thanks to two filaments
  • Mass range 1-200 amu for residual gas analysis, even in the higher mass range
Filament Bakeout temperature: analyzer [°C] Connection I/O interfaces Order number
Tungsten 200 I/O 220 PT M06 241 111